TBD0604550104.jpg@f35a2b4b5c491cd3ea73d6a5a4246337
TBD06045501_B1.jpg@8cdf9341486e707fc68b0cc06a89bc70
TBD06045501_B2.jpg@9e18d0ac403538fccfae570832422a13
TBD06045501_B3.jpg@5cfd0ae55fe4e85aee05730752888300
TBD06045501_B4.jpg@a8f88f71c194012968a3fc1aae4fb6f3
TBD06045501_B5.jpg@c0ebd566f4e7cfaf5a84da2865894f88
TBD06045501_B6.jpg@39799948a2d6d03c7934ca3065884c22
TBD06045501_B7.jpg@77c20bea80ce8a9e0f168347feacaf13
  • Load image into Gallery viewer, TBD0604550104.jpg@f35a2b4b5c491cd3ea73d6a5a4246337
  • Load image into Gallery viewer, TBD06045501_B1.jpg@8cdf9341486e707fc68b0cc06a89bc70
  • Load image into Gallery viewer, TBD06045501_B2.jpg@9e18d0ac403538fccfae570832422a13
  • Load image into Gallery viewer, TBD06045501_B3.jpg@5cfd0ae55fe4e85aee05730752888300
  • Load image into Gallery viewer, TBD06045501_B4.jpg@a8f88f71c194012968a3fc1aae4fb6f3
  • Load image into Gallery viewer, TBD06045501_B5.jpg@c0ebd566f4e7cfaf5a84da2865894f88
  • Load image into Gallery viewer, TBD06045501_B6.jpg@39799948a2d6d03c7934ca3065884c22
  • Load image into Gallery viewer, TBD06045501_B7.jpg@77c20bea80ce8a9e0f168347feacaf13

SINOTIMER STVP-932 80A 3-phase 380V LCD Self-resetting Adjustable Surge Voltage Protector

Regular price
R 1,374.45
Sale price
R 1,374.45
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.


Features:
1. Overvoltage protection
2. Under voltage protection
3. Voltage display (voltage measurement ABC Separate Phase Voltage)
4. Three-phase voltage unbalance protection
5. Phase sequence protection (reverse phase protection)
6. Zero break protection
7. Phase failure protection
8. Overvoltage protection value is adjustable
9. Overvoltage recovery value is adjustable
10. Overvoltage protection action time is adjustable
11. Undervoltage protection value is adjustable
12. Undervoltage recovery value is adjustable
13. Undervoltage protection action time is adjustable
14. Three-phase voltage unbalance protection value is adjustable
15. Three-phase voltage unbalance protection action time is adjustable
16. The power-on delay time is adjustable
17. Fault recovery delay time is adjustable
18. Reset mode selection
19. Troubleshooting
20. Restore factory settings

Parameter:
1. Rated voltage: three-phase four-wire 230V/400VAC 50/60Hz
2. Rated current: 50A, 63A, 80A
3. Overvoltage protection value range: 221V-300V-OFF (default value 280V)
4. Overvoltage recovery value range: 220V-299V (default value 250V)
5. Overvoltage protection action time is adjustable: 0.1 seconds-10 seconds (default value 0.2 seconds)
6. Undervoltage protection value range: 219V-150V-OFF (default value 160V)
7. Undervoltage recovery value range: 220V-151V (default value 180V)
8. Undervoltage protection action time is adjustable: 0.1 seconds-10 seconds (default value 0.2 seconds)
9. Three-phase voltage unbalance protection value range: 10%-50%-OFF
10. Phase voltage unbalance protection action time: 0.1 seconds-10 seconds (default value 1.0 seconds)
11. Power-on delay connection time: 2-255 seconds (default value 2 seconds)
12. Failure recovery delay time: 2-512 seconds (default value 60 seconds)
13. Display mode: LCD
14. Fault indication: segment code characters
15. Sampling method: phase line to neutral line resistance divided voltage AC sampling
16. Grounding system: TT, TN-S, TN-C-S
17. Installation method: guide rail installation
18. Electrical isolation strength: greater than 2000VAC, pulse 2.5KV 1.2/50μS
19. Working environment: temperature -20-50 degrees Celsius, humidity less than 85% altitude: no more than 2000m